The Hidden Hazard: How to Tackle Oil Mist and Smoke for a Safer Workplace

Mark Echols, head of industrial sales at Clean Air Industries, explains where oil mist and smoke come from and why fine particles are a health risk. He compares collector technologies, and covers how to measure concentration and how to size and duct a centralized system.

Video Chapters

Lance Campeau (Marketing, Clean Air Industries): Good afternoon. My name is Lance Campeau, with the marketing department at Clean Air Industries. Welcome to our webinar, “The Hidden Hazard: How to Tackle Oil Mist and Smoke for a Safer Workplace.” I’ll be hosting today’s event, and I’d like to thank each of our guests for attending.

Oil mist and oil smoke are common shop pollutants, usually generated by machining processes like milling, turning and drilling. Simply put, they’re messy, and they compromise worker health and safety. Today we’ll take a closer look at this specific problem.

Our presenter today is Mark Echols, head of industrial sales at Clean Air Industries. Mark has years of experience with this topic and a lot of knowledge about managing this hazard effectively in a variety of manufacturing environments. I’ve seen this presentation a couple of times, and I always learn something new, so I hope it’s as helpful to you as I find it.

Mark Echols (Head of Industrial Sales, Clean Air Industries): Thank you, Lance. I appreciate the introduction, and thank you all for joining today. Like Lance said, I hope you get something out of this. I’ve been doing this for several years and have a decent amount of knowledge around it, but you’re always learning every time you walk into a new plant. There’s always a different challenge, and there’s no one right way or one wrong way to do it.

To start off, I want to talk about oil mist and oil smoke filtration and where it comes from, which is mostly machining processes. These new high-spindle-speed machines can produce very small particulate that is very harmful to your lungs. As you can see in the diagram, oil mist ranges from 5 microns and up all the way down to less than 1 micron. The particles under 1 micron are the ones with very harmful effects on the alveoli in your lungs. They can actually get into your bloodstream through the alveoli. That’s really what we want to key in on: the health and safety side of this.

A little more depth on health and safety standards. It’s pretty interesting: I’m actually at the [SOUTHTEC] show in Greenville today, and a couple of people asked me what the OSHA standard is, and what it is in Japan. I didn’t know offhand, so I looked it up today. In the U.S., the OSHA exposure limit is 5 milligrams per cubic meter. In Europe, it’s 0.5.

I’ve seen a lot of factories in the States that meet the OSHA standard and are still foggy, dirty and slippery. The U.S. standards are really lax. By contrast, the European standard is 0.5 milligrams per cubic meter, and when you walk into a place meeting that standard, it’s very clean, bright and smog-free. You can walk around without worrying about falling down. It’s very nice. Japan is at 3 milligrams per cubic meter, so in between, but still on the high side.

What happens is that coolant and mist escape the machining process and get all over the floors and ceilings. Besides the health hazards, that creates unsafe conditions in the plant.

Oil mist comes from water-based coolants, and oil smoke comes from straight cutting oil. Most processes I see are oil mist, from water-based coolants used in grinding, turning, milling and machining. That’s a lighter mist, though just as dangerous as oil smoke. Oil smoke is heavier and much more concentrated, so it takes twice the filters to handle an oil smoke application as an oil mist application. You’ll see a lot of oil smoke from cold heading, heat treating, forging and even some tube mills. Most tube mills produce oil mist, but some can produce smoke.

We offer nine different collectors, and you can gang some of them together to get twice the CFM. What makes our technology so good is that it’s coalescing fiber-bed technology. In the lower diagram, you can see a microscopic camera video we made of how our media coalesces mist as it enters the filter. The droplets grow and eventually drop out of the bottom of the collector into a catch pan. The catch pan drains to your sump, a filter or however you want to handle the leftover fluid. You can reclaim the coolant or oil once it goes through a filter.

The biggest thing I try to instill in potential and current customers is how little maintenance these collectors need. We guarantee one year of filter life, and what I mostly see in the field is two to three years. Yes, the filters are fairly expensive, but compared with some of the older technology out there, the payback is very short, because you’re not maintaining these units every single month like you do with many others.

The last thing that makes our systems unique is that it’s a centralized platform. You can have one collector serving nine or 10 machining centers at a time. We’ll get into the filter and how it works in a minute.

I mentioned the competition: mechanical, electrostatic and centrifugal filtration systems. They’ve been around since the ’70s. Mechanical is like a bag filter collector, with very short filter life. Most people forget about it, then suddenly see a bunch of smoke in the plant because the filter clogged completely within a month or two.

Electrostatic filtration actually works extremely well; it’s very efficient. But the plates that collect the mist have to be cleaned at least once a month. If you don’t, everything hits the HEPA after-filter, which fills up fairly quickly, and that’s another $500 filter to change out.

Then there’s centrifugal, which you’ll see a lot on OEM machines; they come with them. They work really well on large particulate, 5 microns and larger, but they let the really small particles straight through. They don’t filter that out. You can stop it with a HEPA filter, but you’ll be replacing that HEPA filter every month, or it just doesn’t work. That’s where maintenance becomes a real cost. Like I said, the payback on our collectors is usually less than a year. Even though they cost a little more upfront, they’ll save you a lot of money in the long run.

Here’s how our collectors work, in this cutaway drawing. On the left, dirty air comes into the collector. Stage one filters out anything 1 micron and up. It coalesces and drops to the bottom, and you can see the drain going into a box. We also offer a pump if you want to pump your leftover liquid or coolant somewhere else to reuse it or dispose of it. Anything that gets through the first stage is captured by stage two, which filters particles below 1 micron at about [99.7%] efficiency. That pretty much gets everything. If anything does get through, there’s a HEPA filter on top that’s 99.997% efficient. So the air coming out of our collectors is cleaner than the air you’ll breathe if you walk outside. Very efficient.

Like I said, unless it’s an unusually heavy concentration of mist, you can count on the filters lasting two to three years. I’ve seen some last six and seven years, though those were pretty light applications.

There’s one other option we offer. If you’ve seen a tube mill, it bends a piece of metal, welds it and then dunks it directly into an oil bath or some kind of cooling system. So you’re getting oil mist and weld smoke at the same time. We have a spray system that sprays water on the bottom of the first filter to keep it moist. The last thing you want in these collectors is for the filter to dry out; it will block quickly if it does. So for wire drawing or other dryish applications, we recommend the spray system, and it works really well in those situations. We also have prefilters that try to keep the larger swarf out of the filters. That’s basically how our collector system works. It’s fairly simple.

When we come out, there are specific things we look for in your application to select the correct collector. We bring an air sampler (some people call it a sniffer) that tests a sample of the air and shows us the concentration at the machine outlet or the operator position. I usually take readings in the aisleways, which gives me a good idea of the problem areas in the plant. That’s number one.

Number two: if there’s a slinger on the machine, I’ll put the tube right in the outlet and measure the concentration coming out of that machine. Anything from 2 to 27 milligrams per cubic meter is pretty much going to be a [Zero Mist] unit. Over 27 and up to around 50 milligrams, I’ll probably use one of our [Zero Smoke] units. If it pegs out over 50 milligrams, it’s always going to be our [High Smoke] unit, one of our workhorses. That’s for tube mills, forging, heat treating and cold heading, which are much higher-concentration applications. The last thing you want is the wrong collector on the wrong application, so it’s important to take these readings and know the concentration levels being emitted.

That’s a simple synopsis. If you have a customer you’d like me to visit, it’s a fairly simple way to determine which filter we need to use.

As for CFM, the way our collectors are numbered, like the OM600 to the OM3600, the number is the CFM. Each filter can take around 1,200 CFM on a smoke application and about 1,800 CFM on a mist application [figures unclear in recording]. We also make smaller units called the OMC, which use half filters, so they handle around 600 CFM. Again, it really depends on your application.

These are mostly not machine-mounted collectors. As I mentioned, they’re centralized collectors. Here are some examples. The video on the far left is a tube mill. You can see two different streams of smoke: the first is the welding and the second is the mist. That’s on the collector right next to it, our High Smoke 2400. It’s about the size of a pallet and about 16 feet tall, and it’s our workhorse for really nasty applications, like a tube mill running 12 hours a day, six days a week. I have one of those not far from our plant that I’ve been able to keep a good eye on. We’re over two and a half years on the filter life so far, and they still don’t need to change the filters. They really are our workhorse.

In the third picture from the left are a couple of 2400s ganged together. In this application, I think there are 10 machining centers on those two collectors. You can see where they gang at the bottom. Typically, we exhaust right back into the plant, but in this picture we’re exhausting outside. That was the customer’s spec, so that’s what we gave them.

On the far right are big 3600s. You can’t tell, but there are two of them together, and you can see all the machining centers they’re collecting mist from. So we can go from one machine to 20. It’s just about CFM and knowing your concentration level. We can come out, do the survey, give you a recommendation on what we think is the right approach and get you a quote.

A quick note on duct velocity. For those familiar with filtration: for weld smoke, duct velocity is 2,700 to around 3,200 feet per minute. For plasma and laser dust, which is larger particulate, we speed it up and target around 3,500 feet per minute in the duct. For carbon black, fiberglass and other heavy material that you don’t want falling out in the duct, you run around 4,000 feet per minute. For oil smoke, you’re really between 2,200 and 2,500 feet per minute.

Interestingly, you always want to slope the duct back toward the machine. That way, when you turn the machine off, the fluid left in the ducting drains back into the machine and not into the collector. That saves the customer money in the long run.

Here are a few layouts we’ve done for past customers. They can get as complicated as you need. Again, it’s just a ducting system. We try to avoid obstructions so we don’t have to route the duct up and down. We want to keep it level and slope it back like I said. I think US Duct did this layout for me. I drew it out for them, and they did a 3D layout.

Same type of situation here. This was a CAD drawing I had. I believe that was two 3600s, each picking up eight machining centers. The customer was very happy with it, and it works extremely well. This was a bit more CFM than we actually needed, but these machines had some pretty big gaps where mist was getting out. I had to add a little more CFM to make sure we had negative pressure on each machining center to keep the smoke inside when they open the door.

That’s how we determine how much CFM we’ll need, and it really depends on the machine manufacturer. Some do a really good job of keeping the machine enclosed; some do not. Open lathes and similar machines are extremely difficult applications, because there’s just no way to source-capture that mist. However, most machining centers are fairly easy to do.

Well, I blew through that pretty quickly, didn’t I, Lance?

Lance: You did. I’ll tell you something: my Teams setup got a little messed up here, so we’ll have to do our Q&A on the fly. I’m going to stop sharing my screen.

You mentioned cold heading, and I’ve heard this application mentioned a few times. I’m not 100% familiar with it. Could you explain what it is?

Mark: Cold heading can be a lot of different things. For example, putting a head on a nail. It always uses straight cutting oil, and it can produce a lot of smoke, depending on the application. I’ve seen everything from a lot of smoke to very little. But it is oil smoke, not mist, and it’s very concentrated. You definitely have to use our smoke units on a cold heading application.

Lance: I remember working on a drill back in my shop days. That cutting fluid is heavy-duty, produces difficult smoke and is very nasty stuff.

I have a question here from [Nathan Richie]: “Is it acceptable for the sloped ductwork to connect directly to the unit using a 90-degree elbow? Is it necessary?”

Mark: Acceptable? Yes, of course. I’ve seen our installers connect ducting to the collector a couple of different ways. They can use a sloped plenum, and I’ve seen them build some crazy triangle-looking things to drain everything into the collector.

There are some applications where you don’t want to slope the ducting toward the machine, but toward the collector instead. Wire drawing is one, where they don’t want anything coming back into the cell. You want it all going into the collector.

Lance: So you don’t want the contaminant coming back.

Mark: Correct.

Lance: Could you talk about what kind of cost savings an operator could expect from coolant and fluids that are recaptured or reclaimed? Is there a number, or at least a percentage, you could estimate?

Mark: I really don’t know the estimates for that. Some emulsions can’t be recovered, and some can. It really depends on the coolant they’re using, and most machine operators will know whether it can be recovered. That’s a good question, but I really don’t know the numbers.

Lance: Would you have to refilter the reclaimed fluid?

Mark: Yes. You have swarf and very small particulate that gets into the coolant, and it goes right up with the mist. So you do have to filter it.

Lance: A reminder: if you’d like to ask a question, please submit it using the Q&A function. We’re here to help you understand these applications better.

You mentioned emulsions. Is the lion’s share of what we’d typically use this equipment for water-based emulsions, or oil, or both?

Mark: We can do both. I just see a lot more emulsion-type, water-based coolants than straight oil.

Lance: When it comes to different materials, like machining aluminum, copper or steel, is there variation in the smoke and mist coming off, or does it depend on the spindle speed?

Mark: All of the above. All I care about is the concentration coming out of the machine. That’s what I base my collector recommendation on.

Lance: You mentioned large-scale lathes a moment ago. Say you had a large spindle, 6, 8 or 10 feet. Anyone who’s been in a manufacturing facility with a giant lathe like that knows the smoke goes everywhere. Is it possible to build an enclosure over that space, or even a retractable one?

Mark: Yes, that’s what you’d have to do. Most of the time, those very large lathes have a crane over them, so you’d need to fashion a hood that can close off the space above the lathe and around the edges. You want to contain the mist inside that space, then vent it from there. You’d need a hood that flips up, slides back or something along those lines.

We’ve done those, not necessarily on oil mist applications, but definitely on weld smoke applications. We’ve done several of those hoods. It could definitely be done; we’d just have to take extra care to make sure everything is closed off really well when we build the retractable hood.

Lance: Mark, we’ve had conversations in the past about equipment typically used for oil mist applications. You’ve mentioned slingers and centrifugal-type equipment. Each time we discuss it, I’m reminded that while cost may be a factor, the quality and maintenance levels aren’t comparable. I know you touched on that earlier, but could you expand on it?

Mark: Sure. Electrostatic collectors and centrifugal units (“slingers” is the industry slang for centrifugals) come in a lot of different sizes, specs and CFMs. But the one thing they have in common, especially centrifugals, is that they’re not efficient at all. Like I said, they let small particulate, 3 microns and under, go right out the exhaust. The only way to contain it is to put an after-filter on it, and then all that concentration hits the HEPA filters.

With ours, we’re catching most of the small particles in our stage one and stage two filters, so very little ever reaches the HEPA. That’s why those HEPA filters last two to three years without being swapped. When it’s time to swap stages one and two, we typically swap the HEPA at the same time.

Lance: That needs to be reiterated for people considering these different types of products. When it comes to maintenance and cost, what really stuck out to me is the particulate load hitting the HEPA filter and having to change it much more frequently. We all know how expensive HEPA filters are.

Mark: Some plants I’ve been in have 40 to 60 machining centers in a building, with slingers or electrostatics on every one. If they want to keep a clean plant, somebody has to go around and maintain every one of them every single month. That’ll keep a maintenance person busy full-time. By the time he gets to the last one, he has to start back over.

Lance: And a full-time, union-scale person doing that work weekly or monthly adds up very quickly.

When I think back to my earlier career, I worked in a factory with a large machining shop. They had about 12 units in there and no particularly effective oil mist collection. There were slippery surfaces, and oily tools all over the shop. Could you tell us about a time you went into a shop and experienced something like that?

Mark: Yes. I was in North Carolina; I won’t name the customer, obviously. They knew they had a problem. They had some collection in there, old bag filter-style collectors, and the ducting was leaking everywhere.

That’s one other thing I forgot to mention about ducting: you don’t use regular clamp-together or flanged dust ducting. We use a pipe with neoprene gaskets. It clamps together just like regular clamp-together ducting, but it’s waterproof. It has to be installed correctly, though. You can’t have any angles in it or it will leak. As long as it’s installed correctly, it won’t leak.

Anyway, the guy called me up there because he knew he had a problem and wanted me to come see how much it would cost to fix. I was going around doing my readings with him, and believe it or not, as nasty as the place was, he was still under 5 milligrams per cubic meter. So he wasn’t in danger of getting flagged by OSHA or anything like that.

Lance: Oh, jeez.

Mark: But I actually fell. I turned a corner, in boots, and slipped down. It was bad. As far as I know, they ended up doing nothing. It is what it is.

Lance: I asked because it stuck out in my mind the first day I walked into that shop and noticed how slippery everything was. Nobody seemed to think it was a problem. Being a bit naive, I wondered, “Why don’t you just clean this up?” I didn’t understand there was a cost involved and specialized equipment.

Can you talk a little more about some of the larger projects you’ve seen? You showed the [Mando] example a moment ago, with two 3600 units, and a diagram with eight machining centers per collector, so 16. How many would you typically see in a standard shop?

Mark: At [Mando] down in Georgia, a supplier for Hyundai and Kia, that’s just one line. We’ve probably got 12 or 14 collectors in that place, because I think they have around 80 machines. They’re churning it out; they run 24/7.

But there really is no typical. You get some shops with two machines because they’ve just got a small operation going, and those are the ones where you’ll never put one of our mist collectors. But in shops with eight to 10 machines, especially in a smaller room, you’ll really see the effects of subpar mist collection.

There are a lot of larger machining businesses out there that may have 40 machines. If they have subpar mist filtration, you’ll always see a haze at the ceiling and a guy riding the floor sweeper 24/7. They have to sweep or mop the floor all the time for safety.

Lance: I can just imagine the forklift drivers drifting across the facility, Tokyo Drift style.

Mark: Most facilities do a good job of keeping the floors dry, washed and clean, so you don’t have those slips. But you’re paying two or three people to go through the plant 24/7, or they have a robotic floor cleaner. And anything you touch is still oily, slick and nasty. You can’t even lay your notebook down on anything.

Lance: Well, I think that’s going to wrap it up for us, Mark. Like I said, this is probably the third time I’ve seen you give at least part of this presentation, and I’ve learned something new again, as I always do. I appreciate you taking the time to meet with our guests today.

We’re doing a continuing webinar series at Clean Air Industries. Our next one should be in December; the topic is to be determined. I’d like to invite all our guests to come back and join us for that. Thank you again, everybody, for joining us. Stay tuned for future broadcasts, and we’ll see you then. Until then, have a good night. Thanks, Mark. Thanks, guys.