Skip to main content

Clean Air Industries

NFPA 660 and Dust Hazard Analysis: What You Need to Know

Dr. Chris Cloney of DustEx Research explains what changed in NFPA 660, how the standard is organized and how a dust hazard analysis works. Clean Air Industries engineers then walk through the dust collectors and explosion protection equipment used for compliance, followed by a Q&A on DHA cost, qualifications and testing.

Video Chapters

Featuring: Lance Campeau, Marketing, Clean Air Industries · Dr. Chris Cloney, Managing Director, DustEx Research (Dust Safety Science) · Mark Edgar, Senior Vice President, Clean Air Industries · Evan Harmon, Applications Engineer, Clean Air Industries · Kevin Costello, Senior Mechanical Engineering Supervisor, Clean Air Industries

Lance Campeau, Marketing, Clean Air Industries: Welcome, everyone. Thanks for taking the time to come meet with us today on a very important topic for our industry. My name is Lance Campo. I work with the marketing department at Clean Air Industries, and we’ve prepared a series of webinars for our industry that we’re going to be hosting this year. We’ve done one before; this is our second one. We have some special guests today, and we’re going to be talking about combustible dust and NFPA 660.

We’re excited to have a panel of guests, and our special guest today is Dr. Chris Cloney, managing director at, well, the website is Dust Safety Science. Chris, I think you go by DustEx Research. Is that correct?

Dr. Chris Cloney, Managing Director, DustEx Research: That’s correct, yes.

Lance: Okay. He’ll be giving you the latest breakdown on the changes in NFPA 660 that are coming up. From Clean Air Industries, we have someone who’s no stranger, Mark Edgar, our senior vice president. He’s been a figurehead in the industry for more than 30 years. We also have Kevin Costello, senior mechanical engineering supervisor, and Evan Harmon, applications engineer, all from our Clean Air Industries team.

At this time, I’d like to hand over our presentation to Dr. Cloney. Dr. Cloney, can I call you Chris for this presentation? Oh, you’re muted.

Chris: Yes, you certainly can. I couldn’t get unmuted. Now I am.

Lance: There you go.

Chris: Yes, you can.

Lance: Okay. I’ll invite you to take screen control at this time, and let’s get started.

Chris: Excellent. Thank you, Lance, for the introduction, and thank you to the panel of Clean Air Industries folks that we have here today. I’m excited for the audience as well. I see a couple of familiar faces, Francesco, Terry, Scott, Marty, in the audience, and a ton of other interesting folks whose names I’ve seen around combustible dust. So I’m excited for this session with the group. I want to say thank you to Clean Air Industries for hosting.

In my short contribution to this, we’re going to cover a lot of groundwork. We’re going to cover what the NFPA standards are. We’re going to cover 660: what is it, what’s the same, what’s different, how do you access it, and if you have questions, where do you go to get those answered? And we’ll cover dust hazard analysis briefly, really just to give you enough information to know what kind of resources are available out there in this space, and hopefully get some really good questions going with either myself or the Clean Air Industries team after this session as well.

My background is originally in defense research. I was working with a consulting company that worked with Defence Research and Development Canada, which is our defense industry, on high explosives research. So think TNT, ammonium nitrate, something that goes bang really quickly. I did that for the better part of seven or eight years prior to starting my academic research in the world of industrial dust explosions. I did that from 2011 through to 2018. All told, it took me about eight or nine years to get my academic degree in this.

During that time, I started what eventually became Dust Safety Science, and then the Dust Safety Academy, the Global Dust Safety Conference, Dust Safety Professionals, and now the Combustible Dust Training Institute, which is our most recent rollout and evolution of what we’re doing to educate folks on combustible dust safety.

Our mission since 2018, when we incorporated DustEx Research, is to have at least one year with zero fatalities worldwide from dust explosions by 2038. No, we haven’t had it happen yet. I don’t believe there has been a year since at least the 1900s that we haven’t had a fatality from a dust explosion, just in the US, or at least in North America. So that’s what we’re working towards.

We’ve built a number of educational platforms related to combustible dust safety. I’ve done a lot of talking on the subject. The Dust Safety Science Podcast is up over 300 episodes in the last five years, and I’ve personally been involved in 150 to 200 webinars covering combustible dust. I definitely do not have all the answers, but feel free to ask any question. If I can’t answer it here, and the Clean Air team can’t answer it here, we’ll get your question answered for you. So that’s what we do.

I did mention that we have recently rolled out the Combustible Dust Training Institute, with certifications and training around combustible dust safety. If this is something you’re interested in, just let me know and we’ll discuss that as well.

I did put access to the slides here. I’ve got the slides and a couple of cheat sheets on some of the specific materials. If you want to access them, the easiest way, since my email gets flooded all the time, is to go to LinkedIn, connect with me and message me “slides plus Clean Air,” and I’ll send you these slides afterwards, plus some of the cheat sheets that the team put together. You simply use your phone here, scan that, it’ll take you to LinkedIn, connect and just shoot me that message, and I’ll send you the slides afterwards.

What is the problem with combustible dust? Why are Kevin and Lance and Francesco and Mark and myself here? I guess I added Francesco. He’s on my screen, but he’s not a Clean Air Industries guy. But why are we here talking about combustible dust safety in the first place?

This photo is from the Imperial Sugar Refinery explosion in Savannah, Georgia, one of the more infamous combustible dust incidents. This had a lot of fugitive dust. Several stories of several buildings were completely demolished from secondary, tertiary, fourth-stage and fifth-stage dust explosions. So that’s one example, one scope of the problem.

But the challenge with combustible dust is that it’s much broader than that. This is an explosion with zero fugitive dust. The dust only existed inside the ducting, from a mill grinding application up to the roof, cyclones, down and back into the dust collector. It propagated back into the building and blew the back corner off. No fugitive dust, and a very high level of destruction.

You also have cases where you have explosions in, we’ll call them small pieces of equipment. I mean, that’s not a small dust collector, but bucket elevators and so on. You have large losses with site-wide, secondary, tertiary and four-stage explosions, all the way down to a small piece of equipment. This is a case with a tragic loss of life: an aluminum dust explosion in Kunshan, China, with upwards of 150 fatalities.

And you can have more personal safety issues. This is Kyle Flicker. He was in a coma for several months after a rubber dust explosion in Blaine, Minnesota, I want to say, although I’m not sure I got the state right. It might be Missouri. No, I think it is Minnesota.

The point of showing you these images, cases and examples, and the Clean Air Industries team would be able to tell you this too, is that there’s just a wide range for combustible dust. Just in those short slides, in those three minutes, I talked about rubber, aluminum, wood and grain. I talked about fugitive dust, with dust all over the place and a real lack of cleaning and collection. I talked about no fugitive dust and still an entire loss of a building. We talked about the personal safety impact on one person, and the site safety impact on an entire building.

That’s the big challenge we have with combustible dust in general. We have a lot of different scopes, a lot of different sizes, and a range of different materials and industries that we’re working with. So the overall summary is: wouldn’t it be nice to have a structured way to identify the materials that cause the hazards in the first place, analyze where and when these hazards come up, evaluate what safeguards are needed, then recommend and track progress against improving these safeguards? That’s the sole purpose of the dust hazard analysis process as outlined in the NFPA standards: to give you, or to give a qualified person, that structured way to assess these hazards, given the breadth, width and depth of the challenges associated with combustible dust.

There’s been a lot of talk recently about NFPA 660. Some folks haven’t seen it yet, so just in case you don’t know, NFPA standards are available online for free. Just go to nfpa.org/ followed by the standard number. I’m actually not sure this is true of every standard, but it is of every combustible dust one: 652, 61, [unclear]. If you go to that URL with that number and scroll down, you can click “View free access.” You have to create an account, so it’s not completely free; you have to give up your email. But you can view the entire document. So if you have questions about anything in this presentation, or if you see something and think, “I wonder what that section says,” you can access it. I personally use NFPA LiNK, which I find very quick compared to the old method of printing off reams of paper and trying to flip through the thing to find the material you’re looking for. You can access it free today.

This is the structure of what we’ll call the past NFPA standards. NFPA 652 outlined the systematic procedure for completing a DHA: how to identify the hazards, how to assess them, how to address them, and what management systems to put in place. Then it called out to the green squares, which are the commodity- or industry-specific standards for agricultural, sulfur, metals, wood processing and other dusts. It also called out to the how-to standards: deflagration venting, deflagration prevention and the NFPA 70 electrical code.

That was how the standards aligned. Each one of these was a different document, in a different order, created by a different committee. So it was good in a sense, because you knew what was contained in each one, but it also took a lot of work. You had to read all of 652 and then all of 61 if you wanted to understand what to do in a grain handling facility.

The focus for 660, then, was to combine the fundamental standard and those commodity- and industry-specific standards into one document. The layout is that chapters 1 to 20 are 652, and chapters 21 to 25 are the commodity-specific standards. The really nice thing about laying it out this way is that things are nested. For example, and I’ll probably get this wrong, let’s say section 4.3 would be, I believe, the requirements for owners and operators in a facility handling combustible dust. So that’s what you’d find in chapter 4, section 3. If you want to know the additional requirements for owners and operators in a grain handling facility, that would be 21.4.3. If you want to know the additional requirements for operators in sulfur, it would be 24.4.3.

All the chapters and sections are nested this way. Say bucket elevator protection in the fundamentals chapter is probably up in 9.8. If you want to know bucket elevator protection for a woodworking facility, it would be 25.9.8, and that makes it a lot faster. Before, if you wanted to know about bucket elevators for wood, you’d have to read the entire fundamentals standard and the entire NFPA 664 document, and because things didn’t align, you’d have to try to figure out what that meant. So it was a lot harder. This is a lot faster to get around and a lot easier to use, even though it is a very large document. So that’s the layout for NFPA 660. Again, you can access it free.

These are the general requirements. This is the section I was actually referring to. I guess it’s 4.1, not 4.3. I’m not one of those folks who has the chapters fully memorized and can rattle off the subsections right away.

The requirements for owners and operators in facilities handling combustible dust really have three components. One is identifying the hazards; this is your combustible dust testing. The second is assessing those hazards; these are your requirements to perform a hazard analysis. The third is managing or addressing these hazards. This generally has two components: managing the hazards themselves in the equipment, and management systems like emergency response, training people and housekeeping programs, which go in a separate chapter. Those are your compliance options.

So those are really the three processes you’ll see in the NFPA standard related to dust hazard analysis: identify the hazards by doing your testing, assess the hazards using dust hazard analysis, then go ahead and address the hazards that were identified through the DHA process.

In terms of testing, the first step in identifying the hazards is generally a screening test. This is a cheaper and faster alternative to doing a full suite of tests. If you get the results back from your screening and determine that you do not have a dust explosion hazard, then you don’t have to go through the rest of the requirements related to doing a dust hazard analysis. If your screening test comes back positive, then you go one of two routes. One is understanding your explosibility parameters. Those are the ones outlined in the slide here, like Kst, MEC, LOC, MIE and MIT. It always was the case that you had to look at combustibility and flammability as well, but now NFPA 660 explicitly calls out the particular circumstances where you need to look at flammability parameters too. That gives you an idea of the range of tests that may be required when you’re looking at combustible dust. I think this is one of the cheat sheets that we put in the packet with these slides, if you want to grab those.

I’ll give you a really basic breakdown of the DHA process. One, determine whether you have combustible dust by doing your screening test. If that’s positive, break your process down into a list of nodes, and add nodes for rooms, buildings and building enclosures. Evaluate the hazards, evaluate the safeguards, then document your hazard scenarios and your safeguards, and how they match up against the prescriptive requirements in the NFPA standards, in those chapters on management systems and equipment protection.

Think of it this way. Say we had a really simple process that’s shredding metal components. You have an input hopper, a shredder, an output bin and a dust collector attached to it. We take a sample, probably from the dust collector, do screening tests on it and find that yes, it is explosible. Step two is the nodes. You have your input bin, your shredder, your output bin and your dust collector, plus the ducting between them, which will often be treated as a node, and the room itself will be treated as a node. That’s because you want to assess the hazards at all those locations.

In the room itself, do you have fugitive dust, or the possibility for fugitive dust? If you do, then you need to evaluate the existing safeguards to prevent that, like dust collection or a housekeeping program. Same with the input bin and the output bin. Maybe in the input bin you’re putting, I don’t know, electronic boards. Okay, there may not be a dust hazard there, so you don’t need to deal with it in your DHA, or you can exclude it. On the shredder side, maybe you do have combustible powder that’s built up. At the end of the day, you’re looking to come up with a list of the safeguards that are in place and compare that to the prescriptive requirements in the NFPA standards.

That’s the most basic approach. There are more complicated versions where you can use other DHA methodologies, risk-based assessments and performance-based assessments. This is a really simple example where you’re comparing against the prescriptive requirements of the NFPA standards.

If you want to dive into some more detailed examples, there is one in NFPA 660, which I believe you can access from the free version. Just go to [Annex B], and it gives you a worked-out DHA example. It uses more of a scenario-based approach than the node-based one that I explained, but it will give you an example. There are two books here. Guidelines for Combustible Dust Hazard Analysis is probably the most effective. It has a lot of really good examples and covers both prescriptive requirements and risk-based requirements. So that would be a really good guidebook if you’re looking deeper into this topic. We also have certifications and courses that we’ve built out for this as well.

Just to close out, this is the list of changes in 660 from 652 and the commodity- and industry-specific standards. I’m happy we don’t have to say that all the time anymore. It’ll be good when we don’t have to say “652 plus the commodity- and industry-specific standards.” It’s quite hard to say.

This list is actually in the front of NFPA 660, in the Origin and Development section. It tells you, okay, we tried to make this change with most things staying the same, but here’s the list of things that actually did change with substance between these standards. I’m not going to go through all of them, but I’ll point out a couple that might be relevant to you.

There are now requirements for operational readiness reviews to be done as a management system. This is sometimes called a pre-startup safety review. If the equipment is down for a long enough time, or you’re starting a new piece of equipment, there are requirements for what kind of review needs to be done before you turn it on.

There are new requirements to evaluate self-heating, thermal instability and water reactivity under certain circumstances. That was sort of always included in evaluating fire, flash fire and explosion hazards, but now it explicitly spells out when those would be required as part of your assessment.

Some text has been added in a few places on the level of protection provided by flame-resistant garments. This is newer to the standard, but it’s something that we see running our combustible dust incident database: the protection that employees have when they’re impinged on by a dust deflagration is really important.

There are now specific elements on general safety training and job-specific training, and the frequency with which those need to be completed with your workers. And the last ones on here: some guidance on responding to silo fires, and more requirements added for agricultural and food facilities in terms of the type of equipment that needs to be assessed during a dust hazard analysis.

So that’s it for my contribution. Again, this was really meant to go through 660 at a high level, what’s new, and a little bit on dust hazard analysis, give you some resources you can walk away with, and set the stage for the Clean Air folks to talk through things as well. If you have any questions for me on those topics, please send them through. Again, I’ll send you the slides; just connect with me on LinkedIn and message “slides plus Clean Air,” and the team will know which set of slides to send you. So Lance, without further ado, I’ll give it back to you.

Lance: Thanks a lot, Chris. Just to refresh for anybody that joined us late, you’re watching “NFPA 660 and Dust Hazard Analysis: What You Need to Know.” Our special guest today is Dr. Chris Cloney, and he’s just walked us through, as you’ve heard, some really important updates to the 660 standard. Really interesting. Chris, I do have some questions for you myself, which I’ll save for the end.

At this time, I’d like to hand it over to our Clean Air Industries engineering team, Mark Edgar, Evan Harmon and Kevin Costello, who are now going to discuss some of the equipment solutions that Clean Air Industries offers and some of the applications that we typically see in the field. And I believe, Mark, you’re going to be heading this up from the beginning.

Mark Edgar, Senior Vice President, Clean Air Industries: Yes, Lance, I am. Can you see my screen?

Lance: Yes, sir, I can. Looks and sounds good. I’ll leave it to you.

Mark: All right. Good afternoon, everyone. I’m going to talk a little bit about the equipment that we provide for different solutions that would meet NFPA 660 compliance.

Typically, the dust that we deal with is mostly St 1 dust, with a Kst of less than 200. Those types of materials are things like charcoal, powdered milk, sugar, zinc powder and fiberglass. We can do St 2 dust as well, but that just takes some calculations to make sure that we are within the range. We have dealt with other types of dust as well: plastic dust, food processing dust, tobacco, sugar, wood dust and various metal dusts.

The primary equipment that we use for meeting NFPA 660 compliance is, first, our ATV series dust collectors, which have vertical cartridges. Our second primary equipment series is the ATH, which is a horizontal cartridge collector. The ATV series and the ATH series both use the same size cartridge; one is in a vertical orientation and the other is horizontal.

We also have the ATC cyclone series. Cyclones are mostly used for wood dust, but sometimes they’re used for other applications. You can see in that one picture there, with a horizontal unit, that it’s actually in a thermal spray operation. There were heavy sparks, so it’s being used to remove the sparks. And lastly, we have our ADT series, which is our line of economical dust collectors, with two-cartridge, four-cartridge and six-cartridge models.

The secondary equipment that we would apply to our equipment to meet NFPA 660 compliance includes rupture panels, as you can see in this photograph here, and flameless vents in case the unit is inside.

Rotary airlocks: just a reminder that the rotary airlock needs to meet NFPA 660 compliance. That means eight vanes, a certain tolerance between the vanes and the housing, and outboard bearings.

Explosion isolation valves: here you have what we refer to as a Vigil flap. These go on the inlet duct of the dust collector. Just a reminder that you have to have a certain distance from the Vigil flap to the dust collector, depending on the size of the flap. On the return air, you can return air into the plant, but you need a Vigil flap or explosion isolation valve on that. It will be a fixed flap system and requires a greater distance. It’s really important to get those distances correct, and also to make sure that the ductwork between the Vigil flap and the dust collector meets at least two times the [Pred] of the dust collector.

Here’s a high-speed abort gate, mostly used in wood dust applications. Here you see an explosion vent deflector that can be applied to the vent or rupture panel in cases where it’s pointed towards a parking lot or areas where people pass. This can help shorten the throw of the flame.

We offer chemical suppression systems too. We mostly find those go into the food industry, or sometimes the plastics industry, mostly when the dust that’s been captured is being recycled, or when the distance from the outside wall to where the piece of equipment is located is significant and it’s just easier to have it inside.

And finally, spark detection systems could be used as well. So we offer all of those secondary pieces of equipment that can be applied to our dust collectors. I’m going to hand it over to Evan Harmon now.

Evan Harmon, Applications Engineer, Clean Air Industries: All right, thank you, Mark. I’m going to take us through some installed applications here.

Here we’ve got some pictures of our ATV40. It’s on a fiberglass dust application. On the far right of the screen there, you can see the Vigil flap on the dirty air side going into the dust collector, and of course you can see the rupture panel on the side of the collector itself. And then there’s a dual airlock system, or two rotary airlocks, at the bottom of the hopper.

Here we’ve got an ATV24. It’s on a polycarbonate dust application for an optical lens manufacturer. Again, on the dirty air side, you’ll see an NRV valve and the abort gate. You’ve got the rupture panel on the front face of the dust collector, as well as the rotary airlock at the bottom.

Here we’ve got an ATH 432. This particular application is on a welding and grinding process. You can see that to meet NFPA 68, we’ve got the vent deflector on the right-hand side, closer to where you can see the fan and the stack. What’s not shown is that on the left-hand side of that dust collector, there is a rupture panel to meet code, and of course an NRV valve.

Here we’ve got an application on plastic dust. Again, on the right-hand side of the picture, you can see the NRV valve. There are rupture panels on the left-hand side of the unit, a little out of view of the picture, and on the bottom of the dual hopper, you can see they’ve got rotary airlocks. This particular application was set up so that, as you can see, the duct is kind of floating out here. They got everything set up, then had the electricians come in and make sure everything worked well, to have the least impact in terms of interrupting the process at this particular plant.

One thing I would like to point out is that a lot of the pictures you’ve seen today are applications where the collectors are outdoors. We do, of course, have the capability to do indoor applications. You heard Mark talk about the equipment offerings that allow for that. What we could do is a site visit, where we’d come out, take a look at the application, and help you determine whether it’s an instance where we would have to put the dust collector outdoors or indoors. We don’t always have unlimited floor space with a lot of these applications, and there’s also the challenge of not being near an external wall. So we would help you analyze what would be the best, most cost-effective option for those applications. I’ll hand it over to Kevin.

Kevin Costello, Senior Mechanical Engineering Supervisor, Clean Air Industries: Yeah, thanks, Evan, and thanks, everyone, for joining us today. I would hope that some of our attendees will actually recognize some of these projects that we’ve done. I’m going to finish out by speaking on one more installed project, and then some current projects we’ve been working on here at Clean Air Industries.

This unit is a pretty custom unit for a tobacco application. It contained a chemical suppression system that was food-grade compliant, on the dust collector as well as the inlet and outlet ducting. There’s also an abort gate with a spark detection system on the clean air discharge, which was returning back to the plant, and this unit also had rotary airlocks installed. We designed this unit, and we had to have it PE stamped and also approved by FM Global and a third-party reviewer for this customer. This is actually one of the submittal drawings for that project. It just goes to show some of the ways our engineering department can help our customers, distributors or any prospective clients in getting these projects approved, where you have to make sure your T’s are crossed and your I’s are dotted, so that everything is safe and compliant like it should be.

Then, to go to some of our current projects: this is a 44-inch, 50-horsepower cyclone with a rupture panel, a rotary airlock and some of your standard devices, as well as a vent deflector designed and fabricated by us here at Clean Air Industries and built to NFPA 68 standards.

There’s also a current project we have with a 44-inch cyclone that does not have a blower, but is actually going on the inlet of a cartridge dust collector. It has a rupture panel with a [burst] sensor, as well as a rotary airlock, and a pressure sensor mount that we integrated on the cyclone so it can be tied in with the dust collection system on the cartridge dust collector that’s going with the cyclone.

So we’re very flexible. Our engineering department can help in any way we can to make sure these systems are designed right and meet our customers’ needs. Thank you, everybody.

Lance: All right, thank you very much, Kevin. We’re ready to take questions from our guests. We have one lined up currently. I’m not sure if you can see this on the side of your screen; let me know. The question is: “What is being done to educate the manufacturing space? I have seen universal ignorance, without exception, of anything to do with these requirements.” Is this something that seems to be a problem in the industry? Chris, are you seeing a lack of education in the manufacturing sector?

Chris: Yes. I don’t know if I’d call it universal. I mean, there are 48 folks, or 38 folks, on this call that get it. But it is a big challenge. There are lots of sites that either have no requirements in place, or don’t have a full understanding of the requirements that are needed. You saw a lot of the Clean Air systems that are fully protected. It’s not uncommon to see a site that has only some of those protections, or some that aren’t applied in a very safe manner. Even the deflector plate example that I think Evan or Kevin showed: you see vents pointing directly at an entrance or an emergency exit. Those are all challenges that you see quite commonly, and that’s the importance of doing webinars like this. So not universal, but still a challenge, and still something we’re trying to work on.

Lance: Mark, what would you say in response to that? You’ve seen a lot of people in the field on a month-to-month, week-to-week basis. What can you offer in terms of insight?

Mark: Yeah, Lance, I agree with Chris. I think we see out there that there is a lack of education with end users. And just to point out, it is the end user who is responsible for those situations. I think everyone is meant to have completed a dust hazard analysis by this time. Chris, is that correct?

Chris: Yeah.

Mark: So that dust hazard analysis, part of what it’s meant to do is reveal situations that are unsafe. And I can say personally that I’ve been in factories where, when they see the dollars attached to it, all of a sudden things get a little bit squirrelly. But what’s most important is keeping the people in the plants safe.

Lance: Interesting. I have a question to throw out there. When you’re doing a dust hazard analysis, what is the process for a facility that’s in design and hasn’t been built yet, where some of those processes aren’t producing because the equipment doesn’t exist, and they’re not exactly sure what type of combustible dust might be produced by those new factories? What can you do in that instance?

Chris: Yeah, it’s a really good question, and it’s actually a great place to be. I wish everyone was doing their DHA before the site was built. It presents some unique challenges, but generally not as unique as the challenges that come up on an existing site, trying to deal with old equipment. We generally call it a desktop DHA; that’s the most common name we hear for it. You’re looking at the typical types of materials they’d be handling. You may come up with an envelope for your explosion and testing parameters for your design. It’s really about trying to figure out the best way to integrate, but you can design out a lot of the issues that come up in an existing facility with the right provider.

So it’s actually a great spot to be in. You also have all your documentation at that stage, which is really nice. With a 60-year-old facility, you don’t necessarily have all the design drawings, but if you’re a greenfield site, I’m hoping you have them, otherwise you’re going to be in trouble in the near future. So it’s a good spot to be in. It’s not uncommon; it’s done quite a bit, and there are lots of providers that can do it for you.

Lance: Fugitive dust: that’s a term that I wasn’t familiar with, so I’m glad that you mentioned it today. I’m going to be thinking about that one for a while. We have another question here, for anyone who wants to answer: “Should every customer have their dust tested? Are there applications where it’s fairly obvious that there wouldn’t be combustible dust present?” I guess that’s what they’re trying to get at.

Chris: I can jump in, unless one of the Clean Air folks wants to answer first. You can always opt in and say, “Yes, my dust is combustible.” That’s step one. And you may have a basis of safety that doesn’t require any testing. If you’re going to start sizing vent panels, certain protection mechanisms require you to know the rate at which the explosion is going to happen, and those will require testing. Or if you’re using ignition source control as your basis of safety, you may need to keep your ignition sources below the minimum ignition energy, or the temperatures of surfaces below the minimum ignition temperature. In any of those cases, once we get to designing your safety barriers or your basis of safety, you’ll be looking at which tests you need to run. But there are bases of safety that can be defined that don’t require testing. So it’s not a requirement; you can always opt in.

Now, if you’re not sure whether your dust is combustible, it is really quite hard to say it’s not combustible, unless it’s [unclear].

Lance: Yeah, that’s what I was getting at. I’m thinking of stuff like stone cutting or gypsum.

Chris: But then again, you may not know what the binding materials are in the stone dust and things like that. For a long time, they used to say that welding fumes were oxidized and non-combustible, and it’s still debatable from a physics point of view, to me, whether that’s true. We have lots of fly ash explosions, which is the same thing, but with coal. The point is, we’ve seen more and more weld fume explosions, but it’s not necessarily the weld fumes. It’s all the other stuff that’s going on in the welding application: what you’re cutting, what you’re grinding, the base materials that you’re involved with. So it is quite difficult to opt out. A screening test isn’t terribly expensive. If you’re doing it to save money… I mean, if you’re having fires in your dust collector on your site, that’s another dead giveaway.

Lance: Yeah. You know, it’s difficult to anticipate in a manufacturing facility when workers are going to mix media at a workstation. Let’s say you’re doing welding for a month, then someone comes along and starts to grind aluminum, and that creates a problem. Are you seeing a lot of that in the field in some of your consultations?

Chris: Yeah, there are definitely specific requirements for metals and for mixing, and we do see several cases where mixing metals, say aluminum and iron or other types of metals, can lead to ignition sources inside systems and cause dust explosions. So definitely be careful when you’re mixing. More broadly, yes, it’s hard to opt out without doing testing, but you don’t necessarily need to do testing. There are other bases of safety you could come up with that don’t require it.

Lance: That sounds like it comes back to the point about education, and how there’s a broader issue beyond combustible dust itself. Workers also need to be informed about the hazards that would affect them at the base level.

Another question here, this one for Mark or Kevin: “What kind of service area do you cover, and do you perform the physical installation for your projects in-house?”

Mark: Yeah, I’ll take that. We cover all over the United States. We sell mostly through distribution, so if they opt to contact us, we can go and service our equipment. Installation-wise, we typically try to stay within six or seven hours of our factory, but we do go beyond that in certain circumstances. So we’ll do whatever it takes to keep the customer happy and satisfied.

Lance: All right, one more question here for Chris, with a couple of parts. I’m sure every situation is different, but could you ballpark the cost of a dust hazard analysis based on process, the square footage of a building, or how many facilities a business may have? Is there a starting point you can consider for costing?

Chris: Yeah, it is going to vary depending on your site size. The smallest amount that I’ve seen that really makes any sense, if it’s a really simple operation, just for the manpower to send somebody out for a day, assess the site and write the report, you’re generally looking at maybe $8,000 to $12,000, and $8,000 is starting to get low. What you’re going to get if you go any lower than that is somebody who only assesses parts of the hazards. They come in and say, “Oh, you need a dust collector,” but they’re not looking at your explosion protection systems. They’re not really evaluating anything. If you do the math, you can’t do a whole lot for less than that, and that’s for a really simple site.

The other side is infinite. If you have a really big, complex process and you need people on site for a week to assess it, then it’s tens or hundreds of thousands. But I’d say $12,000 is probably the lowest you’re going to find, and even that is for a really simple process.

On the flip side, generally when you have a shutdown, that’s going to be your biggest expense: the product you’re not making. So if you’re shut down for a day because you have a fire that wasn’t evaluated, you kind of make up the money on the other side.

Lance: It comes back to the old adage: if you think prevention is expensive, think of the cost of an accident. So, the last question for the day: “Who is qualified to perform a dust hazard analysis? What specific skills or qualifications are necessary?”

Chris: Of course. I guess that one’s probably for me as well, is that right? Yeah. So, the NFPA requirements for a qualified person… let me pull up the new 660 to see what’s in here. They generally say, in a very general sense, someone who has experience with the hazard and with the operation, and who knows the dust hazard analysis process.

At Dust Safety Science and the Combustible Dust Training Institute, we break that down into three things. First, do you know combustible dust hazards and the fundamental principles of how fires and explosions occur? That’s step one. Second, you need to know the process itself. It’s great if you’ve done DHAs your entire life in woodworking facilities; you’ve done 50 of them. That’s great. But should you lead the DHA for a new nano-titanium 3D printing application? Well, probably not, because you don’t know that application. So application experience is the second rung. And third is experience actually running the DHA process. Even if you’re an industry expert and you’ve done fundamental combustible dust training, if you’ve never led a DHA, you don’t know how to bring the team together, how to write the report, how to make a good set of recommendations, or how to rank those recommendations in a way that’s useful for the site. That all comes down to DHA facilitation. That’s the third rung.

There aren’t specific standards set by NFPA on what those are, but our certifications are building towards that. We have a Certified DHA Leader program, and the first cohort starts on May 1st, so in two weeks. It builds out those three things: the fundamentals of combustible dust, understanding across a broad range of applications, and how to actually lead and facilitate a DHA. It’s not necessarily one person, but the DHA leader should have enough experience to bring the team together, know what their limitations are, and bring in the subject matter experts from the site that are needed. We’re hoping those requirements will be useful enough for folks to start defining who is a qualified person moving forward.

Lance: That certainly helps to justify some of the costs you were referring to a moment ago, when there’s that level of intricacy in the process. A couple more questions, if you don’t mind; they’re trickling in a bit here. “Is NFPA 660 open for interpretation, or is this standard set in stone?”

Chris: It’s an interesting question. Anything in the chaptered sections is considered “shalls,” so it’s not open for interpretation. Anything in the appendix is open for interpretation; those are “shoulds.” And that also depends on your region, which may not have adopted 660 yet.

So if an insurer says you shall follow 660, then you shall be required to do everything in the chapters, 1 to 20. If you’re in a state that is running the International Fire Code that references 652, there are different years, and different codes reference it in different ways. None of the International Fire Codes are referencing 660 yet, because it’s too new, but they are referencing 652, and if they’re explicitly referencing it, then they’re not explicitly bringing in 660. So there are different ways in which NFPA would be invoked. But in terms of the document itself, the “shalls” are in the chapters, and those shall not be interpreted any other way.

Now, everything’s written in words, and the funny thing with words and people is that we can disagree on what those words actually mean. So that’s a bit of where the gray area comes in with some of this application. But yes, that’s the best way to lay it out.

Lance: Yeah, it’s still very fresh in a lot of people’s minds, I would bet.

Chris: So it’s not changeable. If the question is more about that, the version that’s there is the one. I think it’s probably on a two-year cycle, though I’m not 100% sure about that, but you can submit comments for the next revision cycle. Whenever that new revision cycle comes up, that would be when they’d address it and make changes.

Lance: All right. I just want to end off with a specific equipment question. Mark, if you could, or Evan or Kevin, if this pertains to your expertise: “Do collectors like downdraft tables, which have a lot of open area, still present an explosion hazard, since the unit has more open area than you would need for the size of an explosion vent on the enclosure? Is it really a risk for explosion if you can’t build pressure?” I guess what they’re getting at is that the input side and the output side of the table offer more area for pressure to be relieved. Would you have to put a rupture panel on a downdraft table? Are there fire and explosion mitigation systems that can be added to downdraft tables, or are those even required?

Mark: Yeah, I think the way we review that is that we would rather have a downdraft table that is ducted to a unit outside. Maybe Chris can chime in a little bit on that. But I would say it would just depend on the type of dust and the Kst value, which would affect that. Chris, have you got any thoughts on that?

Chris: Nothing that I could add here. You’d have to look at the specific circumstances and come up with an engineered design. It’s a little bit out of my wheelhouse to figure out on the webinar.

Lance: Yeah, I think that’s a bit outside the scope of this. Chris, I’d invite you to put up that slide again with the QR code, if you don’t mind. I think viewers who missed it would appreciate the chance to scan it and get some of the background information you’ve been referring to. Really excellent stuff. I’m glad that we had the opportunity to come together today and showcase your knowledge and our expertise. Chris, if you could just walk us through this a little bit for anyone who joined late.

Chris: Yeah. We’ve had half a dozen or so people do it already. Just take your phone out, hold it over the QR code and click. That will take you to my LinkedIn profile. Just connect there and shoot me a message saying “slides plus Clean Air.” I was answering the people who came through there, but my team will pick it up in the morning and get anybody else who comes in. We’ll send you the slides, plus a couple of cheat sheets that were made from some of this material. If you have any other questions, you can send them through there too. Like I said, I don’t know all the answers, but I do know a lot of the people. So if there is a question that can be answered, we’ll get the right person to answer it for you.

Lance: That’s excellent. And of course, I’d like to invite anybody who wants to reach out to us here at Clean Air Industries. You can reach us at clean-air.com. We’ll be more than happy to get back to you and answer any technical questions that you didn’t get an answer to today.

I’d also like to remind everybody that this webinar series from Clean Air Industries is ongoing. Our next one will be on educational equipment, coming up, I believe, in June, so be on the lookout for that information. We invite you to come and learn a little bit about the solutions being used in the educational field.

At this stage, I’d like to thank everybody for visiting and meeting with us. And of course, Chris, thank you very much for coming on as our guest today and sharing a lot of very important information on the changes in NFPA 660. I appreciate it, and I’m sure all of our guests do as well.

Chris: Awesome. Thank you, everyone.

Lance: All right, with that, we’ll say goodbye to everybody. Until next time, stay safe out there. Thanks again.

All: Thank you.

Not Sure Which System You Need?