An industrial booth is an enclosed workspace that controls airflow to capture welding fumes, paint overspray, powder or dust at the source. Clean Air Industries designs welding booths, environmental booths, paint booths and powder coating booths that keep contaminants contained, crews protected and finishes consistent.
Choose a standard configuration or have a booth engineered around your parts, floor space and production volume.
| Booth Type | Process | Contaminant Controlled | Typical Use |
|---|---|---|---|
| Welding Booth | MIG, TIG, stick welding | Welding fumes and smoke | Fabrication and manufacturing, vocational training |
| Environmental Booth | Grinding, sanding, prep | Dust and particulate | Surface preparation |
| Paint Booth | Liquid spray painting | Overspray and solvent vapours | Wet coating and refinishing |
| Powder Coating Booth | Electrostatic powder application | Powder overspray | Durable metal finishes |
Clean Air Industries brings air filtration expertise together with RTT Finishing Solutions’ spray booth and finishing equipment manufacturing in Rockwall, Texas. The result is one source for fume extraction, dust control and complete finishing systems.
Yes. Booths can be engineered around part size, floor space, ceiling height and production volume.
A welding booth is recommended when welding is frequent or done in a fixed location. It captures fumes at the source, contains spatter and arc flash, and keeps the rest of the shop cleaner.
Environmental booths contain dust and particulate from grinding, sanding and surface preparation, keeping those processes isolated from painting areas and the rest of the facility.
In a crossdraft booth, air moves horizontally from the front to the back filters. In a semi-downdraft booth, air enters through the ceiling at the front and exits at the back. In a downdraft booth, air flows from ceiling to floor, moving overspray down and away from the part for the cleanest finish.
In the United States, spray finishing operations fall under NFPA 33 and OSHA 29 CFR 1910.107. Local fire marshals and environmental agencies may have additional requirements, so confirm with your authority having jurisdiction.